Motor driven pump system
Features
• Suited to medium-scale equipment and facilities where lubrication points are relatively centralized.
System Operation
Automatic operation is performed based on the lubrication interval set by the system timer on the electric control panel.
When the distributing valve is operated and the specified operation count is reached, this means that all lubrication operations have completed. "High pressure error” alarm is displayed in addition to the "Oil feed time extension”, “Tank Empty” and “Overload operation” alarms.
Circuit Diagram
Note) When this system is used for oil, limit to the two-stage progressive configuration.
Configuration
1 | Pump | AKA, LPP, LBP type |
2 | Distributing valve | MJN, M, MX type |
3 | Cycle switch | |
4 | Electric control panel | EK type |
5 | Reset indicator or automatic relief indicator | MJN, M, MX type |