Providing Reliable Support for Your Diversified Lubrication Production / Plans

Categories and Configurations

Dual line centralized lubricating systems are divided into the following four major types according to drive method and piping system:
(1) Manually operated end type system
(2) Motor driven lance type system
(3) Motor driven end type system
(4) Motor driven loop type system

The following table summarizes the component equipment of each system and their combinations. (For details, refer to the Equipment Manual.)

List of Systems

Drive
system
Piping
system
Pump System
pressure
(MPa)
Change
over
valve
Distributing valve Number
of
lubricating
ports
(max.)
Allowable piping Electric
control
panel
type
Remarks
Format Discharge quantity
(cm3/stroke)
Tank
capacity
(L)
Electric
motor
output
(kw)
Format Discharge
quantity
(cm3/
stroke)
Nominal
diameter
Length
(m)
1500
min-1
50Hz
1800
min-1
60Hz
Manually
operated
End
type
FB-4A 7 cm3/stroke 2 10 Built
into
pump
DW-20type
DW-30type
DW-40type
DW-50type
DV-30type
DV-40type
DV-50type
DV-60type
0.6 to 0.15
1.2 to 0.2
2.5 to 0.6
5.0 to 1.2
1.2 to 0.2
2.5 to 0.6
5.0 to 1.2
14.0 to 3.0
80 20A 30 The two
main
supply
lines
from the
pump
are
dead
ends.
FB-6A 5
FB-42A 3.5 cm3/stroke 2 21 50 15A 60
FB-62A 5
Motor
driven
Lance
type
UE-04AN 21 25 4 0.04 14 LRV-7-W 50 15A 30 EQ-3 The two
main
supply
lines
from the
pump
are
dead
ends.
UE-108AN 30 36 8 0.1 21 LRV-7 100□ 15A 60 EF-3(T)
EF-4(T)
UE-225AN 64 76 25 0.2 200 20A 80
U-25AN 60 72 25 0.4 HV03 EA-5(T)

 

U-30AN 120 144 35 0.4 300 25A 100
U-40AN 195 234 35 0.75 600 25A 90
End
type
U-25AE 60 72 25 0.4 HV03 200 20A 80 EA-5(T) A
pressure
control
valve is
installed
to the
end of
the two
main
supply
lines
from the
pump.
U-30AE 120 144 35 0.4 300 25A 100
U-40AE 195 234 35 0.75 600 25A 90
U-5AE 585 702 90 1.5 SV32MK 2000 40A 150
Loop
type
UE-108AL 30 36 8 0.1 LRV-6 100 15A 90 EF-3(T)
EF-4(T)
. . . . .
.EA-5(T)
The two
main
supply
lines
from the
pump
return
to the
pump
again.
UE-225AL 64 76 25 0.2 200 20A 120
U-25AL 60 72 25 0.4 HV03
U-30AL 120 144 35 0.4 300 25A 150
U-40AL 195 234 35 0.75 600 25A 120
U-5AL 585 702 90 1.5 LRV-36A 2000 40A 200
LPP 29 to
83
35 to
100
Pail
can
0.09 SV02 - - 200 - - - -
LBP 75 to
316
90 to
380
Drum
can
0.2 to
0.4
HV03 500

(Notes)
• For details on oil use of a dual line centralized lubricating system, consult us separately.
• The number of lubricating ports and allowable piping (for loop type: length of loop section, for end and lance types: length from pump to terminal) in the above table are shown as the equivalence of the NLGI consistency #1 grease and DV-30 type distributing valve.
• Replenish the pumps and tank with grease by using a grease filling pump via the replenishing port.
• Standard voltage of electric motor
AC200V 50/60HZ AC220V 60HZ
AC400V 50/60HZ AC440V 60HZ
• Consult us regarding different voltages.

PAGETOP